MRC | Criteria | Characteristic |
---|---|---|
AAXH | PRIME MOVER QUANTITY | 1 |
ACDC | CURRENT TYPE | DC |
ADZC | ENVIRONMENTAL PROTECTION | WATERPROOF |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ATWD | DRUM FLANGE TO FLANGE DISTANCE AND LOCATION | 26.000 INCHES NOMINAL FIRST DRUM |
ATWE | DRUM DIAMETER AND LOCATION | 20.000 INCHES NOMINAL FIRST DRUM |
ATWG | CAPSTAN SPOOL MOUNTING POSITION | HORIZONTAL |
ATWK | CAPSTAN SPOOL QUANTITY | 1 |
ATYG | POWER REQUIREMENT RATING | 50.00 HORSEPOWER |
ATYH | DRUM SURFACE DESIGN | PLAIN |
AWFC | OVERALL LENGTH AND LOCATION | 16.000 INCHES NOMINAL FIRST SPOOL |
FEAT | SPECIAL FEATURES | HAS VARIABLE SPEED ELECTRIC MOTOR |
AWFB | LARGEST DIAMETER AND LOCATION | 18.000 INCHES NOMINAL FIRST SPOOL |
AKPS | DUTY CYCLE | INTERMITTENT |
APHE | OPERATION METHOD | POWER |
BFMF | COOLING METHOD | NON VENTILATED |
ELEC | VOLTAGE IN VOLTS | 230 |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY WESTINGHOUSE ELECTRIC MOTOR AND CONTROLLER |
ATWJ | CAPSTAN SPOOL SURFACE DESIGN | PLAIN |
ATWN | LOAD LIMIT AT SELECTED SPEED AND DRUM LOCATION | 14000.0 POUNDS SINGLE SPEED FIRST DRUM AND 7500.0 POUNDS SECOND SPEED FIRST DRUM |
ATWP | TRAVEL RATE PER MINUTE | 105.0 FEET AND 185.0 FEET |
ATWF | DRUM FLANGE DIAMETER AND LOCATION | 37.000 INCHES NOMINAL FIRST DRUM |
ACSY | FURNISHED ITEMS AND QUANTITY | 1 MOTOR CONTROLLER AND 1 PAWL AND RATCHET |
If You’d Like to Stay Updated On Our Latest Promotions, You Can Download the ASAP Semiconductor App from the App Store and Google Play Store.
Request for Quote