MRC | Criteria | Characteristic |
---|---|---|
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | INCLUDED |
CHGQ | FILTERING SYSTEM | INCLUDED |
SR-5 | MANUFACTURERS CODE | 0YBF0 |
FEAT | SPECIAL FEATURES | DIESEL POWERED 2 SYSTEM |
AYJM | ACCUMULATOR | INCLUDED |
FCLS | III FUNCTIONAL CLASSIFICATION | AA-9.2 |
FTLD | III FUNCTIONAL DESCRIPTION | USED TO TEST AIRCRAFT HYDRAULIC SYSTEMS/COMPONENTS WITHOUT RUNNING THE AIRCRAFT ENGINES OR REMOVING COMPONENTS |
AKYN | FURNISHED ITEMS AND QUANTITY | 88043-224 HOSE 2, 88043-225 HOSE 2, 25024-4 COUPLING 2, 25024-5 COUPLING 2, 24278-100 COUPLING 2, 24376-200 COUPLING 2, 24289-100 COUPLING 2, 24321-700 COUPLING 2, 24256-200 PLUG 1, 24258-200 CHAIN 2, 24333-100 COUPLING 2, AN 894-16-8 BUSHING 2 |
BGST | PRESSURE RATING | 3000.0 POUNDS PER SQUARE INCH MINIMUM AND 5000.0 POUNDS PER SQUARE INCH MAXIMUM |
NTRD | III ENTRY DATE | 10-08-17 |
AAYJ | HYDRAULIC FLUID FLOW RATE | 70.0 GALLONS PER MINUTE |
RDAL | III REFERENCE DATA AND LITERATURE | TO 33A2-2-63-1 |
TMDN | III TYPE/MODEL DESIGNATION | MJ-2A-1 |
SR-5 | THE MANUFACTURERS DATA | |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | PORTABLE HYDRAULIC TEST STAND |
ALBY | USAGE DESIGN | AIRCRAFT HYDRAULIC SYSTEM |
AMQY | INSTALLATION DESIGN | PORTABLE |
RTSE | III RELATIONSHIP TO SIMILAR EQUIPMENT | REFURBISHED4920-01-279-4762 |
SR-5 | DESIGN CONTROL REFERENCE | 88043-1001 |
ANCY | HORSEPOWER RATING | 195.0 |
If You’d Like to Stay Updated On Our Latest Promotions, You Can Download the ASAP Semiconductor App from the App Store and Google Play Store.