NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
9540-01-137-9744 Item Description: Beam Structural | 9540 | 011379744 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mm028338 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
STRUCTURAL | AARN | FABRICATION METHODEXTRUDED |
STRUCTURAL | ABMK | OVERALL WIDTH1 570 INCHES NOMINAL |
STRUCTURAL | ABRY | LENGTH10 000 FEET MINIMUM AND 12 000 FEET MAXIMUM |
STRUCTURAL | ADXJ | LEFT SIDE FLANGE HEIGHT1 593 INCHES NOMINAL |
STRUCTURAL | ADXK | RIGHT SIDE FLANGE HEIGHT2 153 INCHES NOMINAL |
STRUCTURAL | ADXL | LEFT SIDE FLANGE THICKNESS0 063 INCHES NOMINAL |
STRUCTURAL | ADXM | RIGHT SIDE FLANGE THICKNESS0 063 INCHES NOMINAL |
STRUCTURAL | AGTA | BASIC SHAPE STYLEH SHAPE |
STRUCTURAL | AJJB | FIRST TIP RADIUS0 063 INCHES NOMINAL |
STRUCTURAL | BPXD | LEFT SIDE TOP FLANGE DISTANCE TO CENTER OF BOTH FLANGES0 811 INCHES NOMINAL |
STRUCTURAL | BPXF | LEFT SIDE BOTTOM FLANGE DISTANCE TO CENTER OF BOTH FLANGES0 782 INCHES NOMINAL |
STRUCTURAL | BPXG | RIGHT SIDE TOP FLANGE DISTANCE TO CENTER OF BOTH FLANGES1 032 INCHES NOMINAL |
STRUCTURAL | BPXH | RIGHT SIDE BOTTOM FLANGE DISTANCE TO CENTER OF BOTH FLANGES1 121 INCHES NOMINAL |
STRUCTURAL | BPXJ | FILLET RADIUS WHERE TOP LEFT FLANGE JOINS WEB FLANGELEG0 090 INCHES NOMINAL |
STRUCTURAL | BPXK | FILLET RADIUS WHERE BOTTOM LEFT FLANGE JOINS WEB FLANGELEG0 090 INCHES NOMINAL |
STRUCTURAL | BPXL | FILLET RADIUS WHERE TOP RIGHT FLANGE JOINS WEB FLANGELEG0 090 INCHES NOMINAL |
STRUCTURAL | BPXM | FILLET RADIUS WHERE BOTTOM RIGHT FLANGE JOINS WEB FLANGELEG0 090 INCHES NOMINAL |
STRUCTURAL | BPXN | WEB FLANGE THICKNESS0 063 INCHES NOMINAL |
STRUCTURAL | BRFD | WEIGHT PER UNIT MEASURE1 570 POUNDS PER LINEAR FOOT |
STRUCTURAL | CMZY | FIRST TIP STYLERIGHT QUARTER RADIUS |
STRUCTURAL | CMZZ | SECOND TIP RADIUS0 063 INCHES NOMINAL |
STRUCTURAL | CNQJ | SECOND TIP RELATIONSHIP TO FIRST TIPNOT IDENTICAL |
STRUCTURAL | CNQK | SECOND TIP STYLELEFT QUARTER RADIUS |
STRUCTURAL | CNQL | THIRD TIP RELATIONSHIP TO PRECEDING TIPSIDENTICAL WFIRST TIP |
STRUCTURAL | CNQN | FOURTH TIP RELATIONSHIP TO PRECEDING TIPSIDENTICAL WSECOND TIP |
STRUCTURAL | CRZC | RIGHT TOP INSIDE ANGLE90 0 DEGREES NOMINAL |
STRUCTURAL | CSMZ | LEFT TOP INSIDE ANGLE90 0 DEGREES NOMINAL |
STRUCTURAL | CTBR | LEFT BOTTOM INSIDE ANGLE90 0 DEGREES NOMINAL |
STRUCTURAL | CWKK | RIGHT BOTTOM INSIDE ANGLE90 0 DEGREES NOMINAL |
STRUCTURAL | HEAT | HEAT TREATMENTT-6 SOLUTION HEAT TREATED |
STRUCTURAL | MATT | MATERIALALUMINUM ALLOY AMS-QQ-A-20013 ALLOY 7178 |
STRUCTURAL | ZZZT | NONDEFINITIVE SPECSTD DATA7178 ALLOY AND T6 TEMPER |